国产av剧情md精品麻豆,波多野结衣中文字幕久久,国产一区二区三区三级无码,日本一区二区在线播放

埃克森美孚煉油廠2015年事故被認(rèn)定是缺乏足夠的安全管理所致

Hydrocarbon leakage and inadequate process safety management led to an explosion at this California refinery, CSB says.

CSB稱,油氣泄漏和工藝安全管理的不足導(dǎo)致了加利福尼亞煉油廠的爆炸。

Credit: CSB

 

 

美國化學(xué)安全委員會稱風(fēng)險管理的漏洞導(dǎo)致了爆炸

 

美國化學(xué)安全委員會(CSB)在報告中提到,基本工藝安全管理的錯誤(所有美國煉油廠的一些共同現(xiàn)象)導(dǎo)致了位于加利福利亞托倫斯的??松梨跓捰蛷S2015年事故的發(fā)生。

 

CSB主席Vanessa Allen Sutherland說,??松梨跓捰蛷S缺乏恰當(dāng)?shù)娘L(fēng)險管理制度,這意味著“工人們基本上是盲目地在運行每個工藝單元。”

 

事故造成四名工人受傷,無人重傷。爆炸造成碎片橫飛,一些盛裝氫氟酸(HF)的桶從天而降。許多煉油廠在烷基化的工藝中都在使用劇毒的氫氟酸。

 

爆炸發(fā)生在靜電除塵器上,這是煉油廠空氣污染控制系統(tǒng)的一部分。CSB確認(rèn),未被檢測到的碳?xì)浠衔锿ㄟ^流體催化裂解裝置的管道發(fā)生回流,并在除塵器中被點燃。報告稱,在事故發(fā)生時,埃克森美孚煉油廠已經(jīng)關(guān)閉該裂解裝置,計劃對其進(jìn)行維修,但是??松梨跓捰蛷S并沒有將其與其他設(shè)備有效隔離。

 

CSB說,??松梨跓捰蛷S缺乏可以標(biāo)志油氣泄漏的碳?xì)浠衔餀z測設(shè)備。CSB補(bǔ)充道,這種檢測設(shè)備的缺乏是一個全行業(yè)問題。

 

事故關(guān)停了煉油廠,削減了一年多的產(chǎn)量。事故還加劇了附近約15萬居民的擔(dān)憂。

 

在美國,約150家煉油廠中的近三分之一都在使用氫氟酸。即使在極低濃度下,它也會造成人員傷害或致命。

 

CSB還在調(diào)查如果碎片擊中了盛氫氟酸的桶會造成的潛在影響。然而,埃克森美孚公司最近卻將煉油廠出售給了BPF控股公司,并隱瞞了CSB需要的信息,稱這種調(diào)查超出了委員會的權(quán)限。

 

??松梨诟嬖VC&EN,沒有證據(jù)表明此次事件會給社會帶來任何風(fēng)險。此起事故和2015年以來的其他四次事故之后,加利福利亞地區(qū)的監(jiān)管機(jī)構(gòu)已經(jīng)展開了一項關(guān)于在煉油廠更換氫氟酸的研究。他們的目標(biāo)是在年底前公布其研究結(jié)果。

本文經(jīng)《化學(xué)與工程新聞》(美國化學(xué)學(xué)會)許可轉(zhuǎn)載。文章于2017年5月8日首次發(fā)表。

 

U.S. Chemical Safety Board says gaps in risk management led to blast

 

Fundamental process safety management errors—some common to all U.S. refineries—led to a 2015 accident at an ExxonMobil refinery in Torrance, Calif., says a May 3 report from the U.S. Chemical Safety Board.

 

ExxonMobil’s lack of proper protocol to manage risk meant “workers were essentially running the unit blind,” says CSB Chairwoman Vanessa Allen Sutherland.

 

The accident injured four workers, none seriously. The explosion sent debris flying, with some landing near tanks of hydrofluoric acid (HF). Many refineries use this highly toxic chemical in the alkylation process.

 

The explosion occurred in the electrostatic precipitator, part of the refinery’s air pollution control system. Undetected hydrocarbons back-flowed through piping from the fluid catalytic cracking unit and ignited in the precipitator, CSB determined. At the time of the incident, the cracking unit was shut down for planned maintenance but was not sufficiently isolated from the rest of the facility, the report says.

 

The refinery lacked hydrocarbon detection equipment that might have flagged the leak, CSB says. The absence of such equipment is an industry-wide problem, it adds.

 

The accident shut down the refinery and cut output for more than a year. It also heightened fears of some 150,000 nearby residents.

 

HF is used in about one-third of the some 150 refineries in the U.S. It can seriously injure or kill even in small concentrations.

 

CSB is also investigating the potential impact if debris had hit the HF storage tanks. However, ExxonMobil, which recently sold the refinery to PBF Energy, has withheld the information CSB asked for, saying this aspect of the probe exceeds board’s authority.

 

The company tells C&EN there is no evidence the incident posed any risk to the community.

 

Following this incident and four others since the 2015 accident, regional regulators in California have launched a study to consider substitutes for HF at refineries. They are aiming to release their findings by year’s end.

 

This article is reproduced with permission from Chemical & Engineering News (© American Chemical Society).

The article was first published on May 8, 2017.